BURKERT控制器787760安裝簡便

  • 更新時間:2016-07-17
  • 廠商性質:工程商
  • 產品廠地:上海市
  • 訪問次數:714
產品特點:BURKERT控制器787760安裝簡便,
如有需要請與我公司業務員,我們將竭誠為您服務,
其他部分特殊型號也可預訂,本公司在德國設有分公司,報價快,貨期短,價格優勢大。
如需詢價,可我公司業務員、或發送傳真。
詢價時請附上您的公司名稱,姓名及,所需產品型號及數量,我們將盡快給您發送報價。
產品介紹

BURKERT控制器787760是一(yi)種過程(cheng)(cheng)和程(cheng)(cheng)序調節(jie)(jie)器,帶(dai)有zui多四個(ge)(ge)(ge)(ge)調節(jie)(jie)器或(huo)程(cheng)(cheng)序信道。裝置(zhi)的規格為(wei) 144 mm x 130 mm,適(shi)合尺寸(cun)為(wei) 92 mm x 92 的 DIN 控(kong)制(zhi)(zhi)板(ban)凹口和 170 mm 的安裝深度。使(shi)用一(yi)個(ge)(ge)(ge)(ge) 27 色(se) 5“ 彩色(se)顯示(shi)器作為(wei)指示(shi)器。操作界面可(ke)自由設(she)計,根(gen)據(ju)個(ge)(ge)(ge)(ge)人喜好進(jin)行(xing)(xing)調整。在(zai)兩個(ge)(ge)(ge)(ge)可(ke)自由配置(zhi)的顯示(shi)屏界面中,可(ke)根(gen)據(ju)用戶需要放置(zhi)文本、工藝值、背(bei)景圖和圖標(biao)。zui多存在(zai)四個(ge)(ge)(ge)(ge)模擬輸入端(duan)和六個(ge)(ge)(ge)(ge)二進(jin)制(zhi)(zhi)輸入端(duan)以(yi)及六個(ge)(ge)(ge)(ge)用于控(kong)制(zhi)(zhi)輸出(chu)端(duan)或(huo)模擬輸出(chu)端(duan)的插槽。為(wei)了通過一(yi)臺電腦進(jin)行(xing)(xing)舒(shu)適(shi)配置(zhi),還可(ke)提供一(yi)個(ge)(ge)(ge)(ge)安裝程(cheng)(cheng)序。標(biao)準測(ce)量值傳感(gan)器的線(xian)性化已(yi)保存;可(ke)以(yi)對(dui)四個(ge)(ge)(ge)(ge)符合客戶要求(qiu)的線(xian)性化表格進(jin)行(xing)(xing)編程(cheng)(cheng)。借助于數學和邏輯模塊,可(ke)以(yi)對(dui)裝置(zhi)進(jin)行(xing)(xing)調整,使(shi)其(qi)適(shi)合各種不同的調節(jie)(jie)和控(kong)制(zhi)(zhi)任務。通過兩個(ge)(ge)(ge)(ge)串口 RS422/485 或(huo) PROFIBUS-DP,可(ke)以(yi)將裝置(zhi)集成安裝在(zai)一(yi)個(ge)(ge)(ge)(ge)數據(ju)聯(lian)合中。用戶可(ke)通過簡單的方式加裝組件(參見(jian)組塊結構(gou))。通過鎖螺絲對(dui)插式端(duan)子在(zai)背(bei)面進(jin)行(xing)(xing)電氣連(lian)接。

 

BURKERT控制器787760特點:
色彩鮮明的 27 色 5” 彩色顯示器
可自由配置的顯示屏界面
zui多 4 個調節器信道
對包含 1000 個節段的 50 個程序進行動態管理

 

BURKERT控制器787760技術參(can)數: 

Controller structure

P, I, PD, PI, PID

PID

Control loop feedback

Proportional band

0

to 9999 digits

0 digits

Size of the proportional band

 

 

 

 

0 means that the controller structure is out of action!

Derivative time

0

to 9999 sec

80 sec

Determines the differential component of the controller output signal

Reset time

0

to 9999 sec

350 sec

Determines the integral component of the controller output signal

Cycle time

0

to 9999 sec

20 sec

When using a switched output, the cycle time should be chosen so

 

 

 

 

that the energy fl ow to the process is quasi continuous, i.e. as con-

 

 

 

 

tinuous as is practicable without overloading the switching elements

Contact spacing

0

to 999 sec

0 digits

The spacing between the two controller contacts for double-

 

 

 

 

setpoint or modulating controllers, or proportional controllers

 

 

 

 

with an integrated actuator driver

Switching differential

0

to 999 digits

1 digits

Hysteresis for switching controllers with proportional band = 0

Actuator time

5

to 3000 sec

60 sec

The actually utilized operating time of the regulator valve with

 

 

 

 

modulating controllers or proportional controllers with an integrated

 

 

 

 

actuator driver

Working point

-100

to +100%

0%

The output level for P and PD controllers (if x = w then y = Y0)

Output level limiting

0

to 100%

100%

The maximum limit for the output level

 

-100

to +100%

-100%

The minimum limit for the output level

Minimum relay ON time

0

to 60 sec

0 sec

Limits the frequency of switching for switched outputs